Eberbach Header

Model E1000 - Electro-Analyzer

Eberbach's Electro-Analyzer E1000 apparatus is the laboratory standard for determinations of lead, nickel, copper, zinc, antimony, cadmium and other metals by the electro-deposition process. Unit has a finished steel case (30" high) with stainless steel front surface and occupies a table space of 15" x 17". The front panel protects the apparatus from corrosive spillage and fumes. No electrically corrodible components are positioned where material may fall into the cell and alter results. The unit delivers up to 10 volts, 10 amperes DC at each of two positions for simultaneous determinations. Separate ammeters (0-10A) and center-zero voltmeters (10-0-10V) indicate amount and direction of current flow at each position. Polarity reversing switches change the polarity of the electrodes. Current to each position is supplied by individual power transistors controlled by potentiometers. In line fuses protect AC and DC circuits. Stirrers are driven at a constant speed of 620 rpm by a split-phase induction motor. Hollow spindles permit easy vertical adjustment of the glass stirring rods. Power to each stirrer and entire unit is controlled by individual switches with pilot lamps. Heavy-duty platinum electrodes (45 mesh) are recommended for this unit however, lighter weight electrodes may be used. Spring loaded electrode holders grip the electrodes without deforming the stem and may be moved horizontally for centering nested electrodes. For rotating anode techniques a stainless steel rotating anode holder may be substituted for glass stirring rod. This unit ships with 2 E1060 glass agitators.

Specifications:

Stirrer Speed:

620 rpm

Electrical:

115/230V, 50/60Hz

Weight:

125 lbs

Dimensions:

Length - 16.5 in | Width - 15.25 in | Height - 29.5 in

Electro-Analyzer

E1000 - Electro-Analyzer

Electro-Analyzer power unit.

$7,780.00
Heater

E1020 - 115V Heater

For heating Electro-Analyzer samples.

$1,000.00
Cathetometer

E1020.20 - 230V Heater

For heating Electro-Analyzer samples.

$1,000.00
Telescope

E1050 - Electrode Adaptor

Required when using E1140 Rotating Anode.

$225.00
Telescope

E1060 - Glass Agitator

Replacement Glass agitator for E1000.

$80.00
Telescope

E1100 - Anode

The Anode is a platinum electrode, Stationary type. 1" diameter, 2.25" high (overall height is 5.5"), and weighs aproximately 22 grams.

Call For Pricing
Telescope

E1120 - Cathode

The Cathode is a platinum electrode, Stationary type. 2" diameter, 2.25" high (overall height is 5.5") and weighs aproximately 31 grams

Call For Pricing
Telescope

E1140 - Rotating Anode

The Anode is a platinum electrode, Rotating type. 0.5" diameter, 2" high (overall height is 5.5") and weighs aproximately 14 grams

Call For Pricing